Bảng mã lỗi AC Spindle Fanuc A06B-6062, 6063, 6064-xxx

Trong bài viết này RITECH sẽ cung cấp mã lỗi dòng AC Spindle Fanuc các model A06B-6062-H206#H500 , A06B-6062-H208#H500 , A06B-6062-H212#H500 , A06B-6062-H215#H500 , A06B-6062-H218#H500 , A06B-6062-H222#H500 , A06B-6062-H206#H500 , A06B-6063-H206#H510 , A06B-6063-H208#H510 , A06B-6063-H212#H510 , A06B-6063-H215#H510 , A06B-6063-H218#H510 , A06B-6063-H222#H510 , A06B-6064-H201#H520, A06B-6064-H202#H520 , A06B-6064-H203#H520 , A06B-6064-H030#H520, A06B-6064-H040#H520, A06B-6064-H301#H520 , A06B-6064-H302#H520 , A06B-6064-H303#H520 , A06B-6064-H305#H520 , A06B-6064-H306#H520 , A06B-6064-H308#H520 , A06B-6064-H312#H520 , A06B-6064-H313#H520 , A06B-6064-H315#H520 , A06B-6064-H318#H520 , A06B-6064-H322#H520 , A06B-6064-H326#H520 để các bạn dựa vào mã lỗi có thể biết nguyên nhân hỏng hóc các bộ spindle Fanuc là do đâu
[toc]

Bảng mã lỗi AC Spindle Fanuc

Alarm “A” display ROM abnormality

ac spindle alarm a

AL-01 Motor overheat

ac spindle alarm 01

AL-02 Excessive speed deviation

ac spindle alarm 02

Checking of speed feedback signal Observe the speed feedback signal with an oscilloscope after turning on power and setting the rotation command off (motor stopped and drive power set off), Observe the test points indicated below, while turning the motor slowly by hand.

check feedback

AL-03 Blown fuse in DC link section

This alarm indicates that the fuse (F4) in the DC link sectionsis blown. In this case, the transistor module may have failed. Replace it according to Section 6.3. For the mounting location of fuse F4, see Section (5) or (6) in Appendix 6.

AL-04 Input fuse blown Input power open phase

ac spindle alarm 04

AL-05 Control power supply fuse blown

ac spindle alarm 05

AL-07 Excessive speed

ac spindle alarm 07

AL-08 High input voltage

ac spindle alarm 08

AL-09 Heat sink is overheated.

ac spindle alarm 09

AL-10 Input power voltage drops

This alarm indicates abnormally low AC power voltage (- 15% or less).

This alarm may be generated even during momentary power failures.

AL-11 Overvoltage of DC link circuit. (Regenerative circuit is faulty l – – Regeneration failure)

ac spindle alarm 11

AL-12 Overcurrent flows to DC link circuit.

ac spindle alarm 12

AL-13 CPU inter data memory alarm

AL-16 External data memory (RAM) Replace memory (RAM).defective

ac spindle alarm 16

AL-18 Program memory data (ROM) defective

ac spindle alarm 18

AL-19 U-phase current detector circuit defective

ac spindle alarm 19

AL-20 V-phase current detector circuit defective

ac spindle alarm 20

AL-24, 25 CNC power supply is OFF

ac spindle alarm 24